Exit & Emergency Lighting
Fire System Services also provides maintenance services for
exit
& emergency lighting systems. In accordance with Australian Standards 2293.2
emergency lighting systems are required to be certified periodically by conducting
a 90 minute battery power down (discharge) test.
This test certifies that all the exit & emergency
lights are functional and batteries sustain their charge for 90 minutes
during a power black out or building fire. We offer a full backup service where
the
light
fittings
can
be tested, maintained and repaired in the field,
or returned to our workshop for bench testing.
We supply a full range of Nickle Cadmium battery packs and Sealed Lead Acid batteries.

click on to see our range of batteries
Stanilite Exit & Emergency lighting systems
Fire System Services recommends and supplies Stanilite lighting systems. Email us for competitive prices on your exit & emergency lighting requirements

Changing
from exit to running man
Answers relating to changing
diffusers from exit to running man.
Please qlick on to view the PDF.
Cold Cathode Technology

The Stanilite Cold Cathode lamp element has two solid ferrous cathodes in a Tri-phosphor
coated medium voltage discharge lamp. The lamp element is installed in a tough
7mm diameter outer protective glass housing with rugged wedge shaped ends. The
lamp is the same length as a 10w fluoro lamp.
RELIABILITY
As a Stanilite's Cold Cathode lamp dose not have frail
filaments, it dose not burn-out....the most common reason conventional EXIT's
fail!
ENERGY SAVINGS
Stanilite Cold Cathode technology offers significant Energy
savings (up to 300%!) over competing 8/10w Exits.
Peel Off Arrow Exit Light Diffusers

Often time gets wasted on those last few exit light diffusers to complete an
installation. You may find that you need a diffuser pointing the opposite
way at the last moment or have to do a major changes to a layout .....either
way, getting the right diffusers in the time has always been frustrating.
Stanilite Performance Exit fittings use "silk screen peel-off" arrows combining the quality of a silk-screened diffuser with the long-term durability of modern polymers. This means one diffuser can now be configured in one way or four ways to indicate direction, straight out of the box!
Economy

Economy:
10w maintained / non maintained indoor exit lighting. Wall or ceiling mounted.
Nickle cadmium battery pack, 2 hour emergency duration.
When ordering please specify if you require a wall or ceiling diffuser.
Economy
Jumbo Quickfit

Jumbo Quickfit: 18w sustained
indoor exit lighting. Wall or ceiling mounted.
Nickle cadmium battery pack, 2 hour emergency duration.
Jumbo
Quickfit
Legend

Legend: 10w maintained exit light. Wall
or ceiling mounted,
can
be recessed into the ceiling for a flush finish.
Nickle cadmium battery pack, 2 hour emergency duration.
Legend
Quickfit

Quickfit: 10w maintained exit light can also be provided in 4w Cold Cathode. Wall
or ceiling mounted.
Nickle cadmium battery pack, 2 hour emergency duration.
Quickfit
Quickfit Theatre


Theatre quickfit diffusers do not come with peel off arrows,
please specify if you need an arrow and on which side.
Quickfit Theatre: 10w maintained exit light can also be provided in 4w Cold
Cathode. Wall
or ceiling mounted.
Nickle cadmium battery pack, 2 hour emergency duration.
The quickfit theatre is a purpose engineered Black "Theatre Mask" Exit
with specially
designed "light proof" diffuser. The unit is designed for use in
low ambient light - eg; theatres, auditoriums. The unit is also available with
discreet
downlight
option.
Vandalproof

Vandalproof: 10w maintained exit light perfect wear exit lights are subject
to knocks or vandalism. Wall or ceiling mounted.
Nickle cadmium battery pack, 2 hour emergency duration.
Vandalproof
Coolroom

Coolroom: 10w maintained exit lights designed for cold room applications
or external conditions.
Weatherproof rating IP65 (house proof).
Nickle
cadmium battery pack, 2 hour emergency duration.
Coolroom: 18w non maintained emergency light battens
for cold room applications or external conditions.
Weatherproof rating IP65 (house proof).
Nickle
cadmium battery pack, 2 hour emergency duration.
Coolroom
Spitfire

Spitfire: indoor non maintained recessed emergency luminaire. Ceiling mounted
only.
Nickle cadmium battery pack, 2 hour emergency duration.
Lampheads can be fitted with acrylic domes or wireguards for
lamp security, also come housed in IP65 weatherproof enclosures.
Spitfire
7w
Spitfire
10w
Nightray Emergency Light

10w Batten:10w
maintained / non maintained indoor emergency lighting. Wall or ceiling mounted.
Available with Prismatic or Opal type diffuser.
Nickle cadmium battery pack, 2 hour
emergency duration.
Nightray Emergency lights are a 10w non
maintained fittings, fitted with sunset switches. When the light level falls
to dusk the non maintain units switch over to maintained
mode, when it's dawn they switch over to non maintained mode hence given
you a night light whilst having the benefits of an emergency
light.
Theses fittings are ideal for institutions, nursing homes and hospitals.
28w & 32w Saturn Emergency Light

Saturn 28w & 32w range of emergency fittings have been designed to deliver the
efficiency and reliability of Stanilite's
premium linear emergency batten range
into a more
architecturally pleasing circular emergency fitting. Saturn emergency fittings
are suitable
for wall or ceiling installations in many commercial applications including office
areas, foyers, and stairwell areas.
Saturn
10w Batten Emergency Light

10w Batten:10w
maintained / non maintained indoor emergency lighting. Wall or ceiling mounted.
Available with Prismatic or Opal type diffuser.
Nickle cadmium battery pack, 2 hour emergency
duration.
Economy
18w & 36w Batten Emergency
Light
18w & 36w Batten:
maintained / non maintained indoor emergency lighting. Wall or ceiling mounted.
Available with Acrylic prismatic diffusers or zinc coated steel wireguards.
Nickle cadmium battery pack, 2 hour emergency
duration.
Batten
18w & 36w
Batten
Premium
Batten
Weatherproof
Flood Unit

Flood Unit: indoor 12v non maintained emergency light, designed for large area
illumination. Wall mounted only.
Sealed lead acid batteries, 2 hour emergency duration.
Flood
Economy
Flood
Premium
Stanilite Battery Pack's

We are able to provide the full range of battery packs for Stanilite fittings.
The battery packs are provided with the quick connect
terminals so no electrical wiring is required.
Battery
Pack's
Stanilite Acessories

90 Minute Test Timers: This test switch is installed between
the circuit breaker and exit/emergency light fitting. After the switch is manually
activated to test mode, the switch automatically resets to normal operating
mode after 90 minutes. This elimates the need to manually reset the circuit
breaker after performing a 90 Minute Discharge Test and reduces the cost of
replacing run down batteries if the light fitting is inadvertently left in test
mode.
Test
Timers
Maintenance Log Books: These Log Books assist in keeping accurate records for
Exit & Emergency Lighting Systems i.e. discharge
tests, battery & lighting tube replacements, fitting repairs & replacements,
etc.
Exit Signs

Apart from electrical exit & emergency lights we can supply illumines stick
on exit signs.
Ektor LED's Exit / Emergency Lighting
Ektor
RAZOR Exit & Emergency Light range
Ektor RAZOR is a range of Exit lighting with LED technology, There is no Fluro tubes to replace.
The Razor emergency exit sign product range is an extremely efficient
and reliably designed exit sign.
The Razor's construction allows recessed ceiling mounting and provides single
or double sided viewing.
The Razor is equipped with a 50,000 hour LED Light source, which reduces the servicing costs, but also reduces the power consumption of the product.
The Razor's decal can be changed easily without removal from the roof and the diffuser can be installed after painting or construction is finished.
The Razor's electronic design allows for a wide operation for different supply voltages, while minimizing its power consumption which starts from 2.2 watts.
If you are interested in the next generation
of LED technology exit lighting please open the above PDF catalouge
and contact us for a price.
Click on the link below to compair the cost & carbon savings.